Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.